Size-based separation in microfluidic systems is a technique that allows the separation and sorting of particles or cells based on their size. In this work, we propose a microfluidic device that consists of cylindrical electrodes. The particle motion equation is solved by the finite element method in the presence of dielectrophoresis and thermal forces. In the present work, the effect of particle size, applied electric potential, electrode size, and electrode position on the dynamics of particle motion is investigated. Numerical results show that for the proposed microchannel, four particle separation regimes are observed. The influence of various parameters can lead to different regimes for particles separation. These regimes guide particles to different outlets or particles to be trapped. These regimes are influenced by controlling parameters such as particle size, applied electric potential, electrode size, and electrode position. The response surface method is applied to modeling and predicting the variation in responses. The results of response surface method indicate that the separation diagram of particles based on their size has a strong dependence on the electrode position. The response surface method has been shown to accurately predict variations in the critical size of particle. The results obtained from the response surface method indicate that average prediction error of critical radius of particle in the separation diagram is less than 8%.

Access this article

Log in via an institution

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Karthick S, Sen AK (2018) Improved understanding of acoustophoresis and development of an acoustofluidic device for blood plasma separation. Phys Rev Appl 10(3):034037

    Article  Google Scholar 

  2. Yan S, Zhang J, Alici G, Du H, Zhu Y, Li W (2014) Isolating plasma from blood using a dielectrophoresis-active hydrophoretic device. Lab Chip 14(16):2993

    Article  Google Scholar 

  3. Park SW, Lee J, Yoon H, Shin S (2021) Microfluidic investigation of salinity-induced oil recovery in porous media during chemical flooding. Energy Fuels 35(6):4885–4892

    Article  Google Scholar 

  4. Saadat M, Yang J, Dudek M, Oye G (2021) Microfluidic investigation of enhanced oil recovery: the effect of aqueous floods and network wettability. J Pet Sci Eng 203:108647

    Article  Google Scholar 

  5. Yang L, Sun L, Zhang H, Bian F, Zhao Y (2021) Ice-inspired lubricated drug delivery particles from microfluidic electrospray for osteoarthritis treatment. ACS Nano 15:20600–20606

    Article  Google Scholar 

  6. Shourabi AY, Kashaninejad N, Saidi MS (2021) An integrated microfluidic concentration gradient generator for mechanical stimulation and drug delivery. J Sci Adv Mater Dev 6(2):280–290

    Google Scholar 

  7. Kadivar E (2016) Droplet trajectories in a flat microfluidic network. Eur J Mech B Fluids 57:75–81

    Article  MathSciNet  Google Scholar 

  8. Chaghagolani HO, Kadivar E (2023) Numerical study of droplet sorting in an asymmetric Y-junction microfluidic by BEM and LS method. Microfluid. Nanofluidics. 27:14

    Article  Google Scholar 

  9. Olfat M, Kadivar E (2023) Particle separation based on dielectrophoresis force using boundary element method and point-particle approach in a microfluidic channel. Microfluid Nanofluid 27(12):83

    Article  Google Scholar 

  10. Yang F et al (2019) Extraction of cell-free whole blood plasma using a dielectrophoresis-based microfluidic device. Biotechnol J 14(3):1800181

    Article  Google Scholar 

  11. Zhang Y, Chen X (2020) Dielectrophoretic microfluidic device for separation of red blood cells and platelets: a model-based study. J Braz Soc Mech Sci Eng 42(2):89

    Article  Google Scholar 

  12. Pakhira W, Kumar R, Panwala FC, Ibrahimi KM (2023) Microfluidic design for continuous separation of blood particles and plasma using dielectrophoretic force principle. Comput Assisted Methods Eng Sci 30:323–345

    Google Scholar 

  13. Rasel AFK, Seyler SL, Hayes MA (2023) A numerical study on microfluidic devices to maintain the concentration and purity of dielectrophoresis-induced separated fractions of analyte. Anal Bioanal Chem 415(20):4861

    Article  Google Scholar 

  14. Sharbati P, Sadaghiani AK, Kosar A (2023) New generation dielectrophoretic-based microfluidic device for multi-type cell separation. Biosensors 13(4):418

    Article  Google Scholar 

  15. Alkhaiyat AM, Badran M (2023) Numerical simulation of a lab-on-chip for dielectrophoretic separation of circulating tumor cells. Micromachines 14(9):1769

    Article  Google Scholar 

  16. Mahani MA, Karimvand AN, Naserifar N (2023) Optimized hybrid dielectrophoretic microchip for separation of bioparticles. J Sep Sci 46(19):2300257

    Article  Google Scholar 

  17. Mishchuk NA, Takhistov PV (1995) Electroosmosis of the second kind. Colloids Surf A 95:119

    Article  Google Scholar 

  18. Li A, Ahmadi G (1992) Dispersion and deposition of spherical particles from point sources in a turbulent channel flow. Aerosol Sci Technol 16(4):209

    Article  Google Scholar 

  19. Jones TB (2003) Basic theory of dielectrophoresis and electrorotation. IEEE Eng Med Biol Mag 22:33

    Article  Google Scholar 

  20. Valero A, Braschler T, Renaud P (2010) A unified approach to dielectric single cell analysis: impedance and dielectrophoretic force spectroscopy. Lab Chip 10:2216

    Article  Google Scholar 

  21. Ghoshal K, Bhattacharyya M (2014) Overview of platelet physiology: its hemostatic and nonhemostatic role in disease pathogenesis. Sci World J 2014:781857

    Article  Google Scholar 

  22. Shvalov AN, Soini JT, Chernyshev AV, Tarasov PA, Soini E, Maltsev VP (1999) Light-scattering properties of individual erythrocytes. Appl Opt 38:230–235

    Article  Google Scholar 

  23. Wu L, Lanry Yung LY, Lim KM (2012) Dielectrophoretic capture voltage spectrum for measurement of dielectric properties and separation of cancer cells. Biomicrofluidics 6:014113

    Article  Google Scholar 

  24. Acharyya S, Matrisian L, Welch DR, Massague J (2014) The molecular basis of cancer, 4th edn. Elsevier, AMsterdam, pp 269–284

    Google Scholar 

  25. Box GEP, Wilson KB (1951) On the experimental attainment of optimum conditions. J R Stat Soc Ser B (Methodol) 13:1

    Article  MathSciNet  Google Scholar 

  26. Mahmoodi V, Sargolzaei J (2014) Photocatalytic abatement of naphthalene catalyzed by nanosized TiO2 particles: assessment of operational parameters. Theor Found Chem Eng 48:656

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

  1. Department of Physics, Shiraz University of Technology, Shiraz, 71555-313, Iran

    Erfan Kadivar & Mostafa Olfat

  2. Department of Mechanical Engineering, University of Gonabad, Gonabad, Iran

    Seyed Morteza Javadpour

Corresponding author

Correspondence to Erfan Kadivar.

Additional information

Technical Editor: Ahmad Arabkoohsar.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kadivar, E., Olfat, M. & Javadpour, S.M. Numerical study and statistical analysis of effective parameters on dielectrophoretic separation of particles using finite element and response surface methods. J Braz. Soc. Mech. Sci. Eng. 46, 473 (2024). https://doi.org/10.1007/s40430-024-05058-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s40430-024-05058-8

Keywords